CHECKOUT AND ADJUSTMENT

After the oven is installed and the gas connected, all gas connections MUST be tested for gas leaks. Be sure that elec-
tricity is off before turning on the gas supply. Test with pressure gauge or apply soapy solution or leak detector solution
on ALL gas connections. Repair any leaks that may appear before operating oven.
THE REGULATOR IS SET FOR USE WITH NATURAL GAS. FOR USE WITH LP GAS, THE REG-
ULATOR MUST BE CONVERTED. The gas pressure regulator is located in the compartment behind the
control frame. Removecontrol frame (see instructions below), loosen and slide the control mounting plate
out to gain access to the pressure regulator.

TO REMOVE CONTROL FRAME

t
v
(TYPICAL CONSOLE)
1 Remove bezel nut from oven light switch by turning counterclockwrse
2. Remove all other knobs by pullrng straight forward,
3. Remove front 3 Phillips screws under control frame and 2 Phillips screws on top portlon of control
frame. Be sure to hold control frame in place.
4. Pull control frame forward.
To convert the regulator for LP gas, remove the regulator access cap (see below). Reverse cap, so that “LP” In
cap recess is showing when cap is in place. Return cap to regulator and tighten. The regulator
IS
set at 4” water
column (W-C.) for use with natural gas and 10” W.C. for use with LP gases. In order to check pressure
regulator, the inlet test pressure must be at least one (1”) W.C. greater (5” for natural and 1 1” for LP) than
setting. Maximum pressure to regulator must not exceed 14” W.C.

\

PRESSURE REGULATOR