The Adaptive Defrost Control allows the unit to enter a defrost mode only when it is needed. When powered up for the first time, the control will initiate a defrost cycle after 8 hours of compressor run time. By monitoring the duration of defrost heating time and compressor run time, the control will continuously adapt the time between defrosts to optimize efficiency. Time between defrost periods will vary from 8 to 100 hours.
For the first 5 minutes of defrost, the heater is on continuously. It then cycles off for 1 minute and back on for 2 minutes. It continues to cycle at this ratio until the
The evaporator fan motor will start 40 seconds after the compressor is energized and continue for 2 minutes when it cycles off.
After defrost, fan delay prevents unnecessary movement of warm moist air through the refrigerator by chilling the evaporator prior to starting the fan. Immediately after the defrost drip time the compressor starts, but the evaporator fan is delayed by 4 minutes 15 seconds. The baffle will be closed during defrost and remain closed for 10 minutes after defrost.
The Over Temperature Alarm sounds and the indicator light flashes when either the refrigerator temperature exceeds 48°F (9°C) or the freezer temperature exceeds 15°F
NOTE: When the refrigerator is first started, it may take longer than 1.5 hours to reach the customer selected settings. It is normal for the Over Temperature Alarm to sound/flash.
The Water Filter Indicator displays the condition of the filter. Both dispenser usage and time elapsed are monitored to determine the filter’s status. A green light indicates a good filter, yellow means order a replacement filter and red means replace the filter. To reset the counter, press and hold the reset button for two seconds.
LED color | Description | Gallons | Time (days) |
|
|
|
|
Green | Good Filter |
|
|
|
|
|
|
Yellow | Order Filter |
|
|
|
|
|
|
Red | Change Filter | 500+ | 365+ |
|
|
|
|
When selected, Max Cool changes the refrigerator setting to 34°F (1°C) and the freezer to
6