Step | Component tested Comment | Results |
Freezer Thermistor | The board will check the |
| resistance of the thermistor |
| and display the results |
| on the water filter indicator. |
Refrigerator | The board will check the |
Thermistor | resistance of the thermistor |
| and display the results on |
| the water filter indicator. |
Good (Pass/green)
Change (Fail/red)
Evaporator Fan | The control switches neutral to the evaporator fan motor. Confirm |
Motor | evaporator fan motor is running and operating correctly. |
|
|
Compressor and | Line voltage is switched to the components. Confirm components are |
Condenser Fan Motor | running and operating correctly. |
|
|
Air Baffle Motor | The control switches neutral to the baffle motor. The baffle motor |
| continues to run until advanced to step 6. Confirm that the evaporator |
| fan motor is running and the air baffle is opening and closing. |
|
|
Defrost Heater and | Line voltage is switched to the heater circuit. Confirm that the heater is |
operating. | |
| NOTE: If the |
| insulated jumper. |
|
|
Exit | Press and hold the Water Filter Indicator Reset button for 2 seconds |
| until you hear a beep. |
|
|
022774
519476
1016701
1514360
2012379
2510698
309269
358050
Temperature Resistance (Fahrenheit) (Approximate Ohms)
505348
554688
604118
653625
703197
752826
802503
852221
901975
12