When the refrigerator thermistor reaches the cutout temperature, the control energizes the baffle motor to close the door.
L1 |
|
| N |
|
|
| ELECTRONIC CONTROL |
|
|
| |
|
| AIR BAFFLE ASSEMBLY | BAFFLE |
|
|
| TRIAC |
Y/R | 4 | 6 OR/BK | WH |
|
|
BK 5
MOTOR RUNNING AND DOOR CLOSING
When the baffle is fully closed, the switch opens interrupting power to
L1 |
|
| N |
|
|
| ELECTRONIC CONTROL |
|
|
| |
|
| AIR BAFFLE ASSEMBLY |
|
Y/R | 4 | 6 OR/BK | WH |
|
| ||
BK | 5 |
|
|
MOTOR OFF AND DOOR FULLY CLOSED