4.Push the right end of the motor mounting plate up and snap it into the spring tab.

NOTE: The spring tab should be outside the slot in the mounting plate.

A

7.Go to the “Make Electric Power Supply Connection to Range Hood” section.

Install Range Hood In-Line (External Type)

Blower Motor

NOTE: Your range hood requires you to purchase either an internal type or an in-line (external type) blower motor system. See “Blower Motor System” in the “Accessories” section.

B

A. Motor mounting plate

B. Spring clip

5.Align mounting holes in motor mounting plate with motor mounting clip nuts and install 6 x 16 mm screws and

6.4 mm lock washers (quantity 2 for single motor; quantity 5 for dual motor).

C

B

A

A. Screw with lock washer

B. Mounting hole in motor mounting plate

C. Clip nut (6 mm)

6.Attach power supply connector from the range hood to the connector on the blower motor assembly wiring box.

A

B

A. Wiring box connector

B. Power supply connector from range hood

Prepare for Mounting the In-Line Blower System

The in-line blower system must be fastened to a secure structure of the roof, ceiling, wall, floor, or new or existing frame construction. The 4 holes on either the inlet (bottom) side or the outlet (top) side of the blower must be used to mount the in-line blower system to the structure.

NOTE: The mounting hole locations must span the studs. Additional stud framing may be required. Plywood may be used to span open areas between ceiling joists or roof rafters to aid installation. This structure must be strong enough to support the weight of the in-line blower system (50 lb [22.6 kg] min).

Prepare the In-line Blower System

WARNING

Excessive Weight Hazard

Use two or more people to move and install in-line blower motor system.

Failure to do so can result in back or other injury.

1.Using 2 or more people, move the in-line blower motor system to the mounting location.

2.Remove the 10 screws from the front cover of the in-line blower motor housing and set them aside.

3.Remove the front cover of the in-line blower motor housing and set it aside.

NOTE: To make the blower motor housing easier to mount, the blower motor assembly can be removed. If you do not want to remove the blower motor assembly, proceed to “Install In-line Blower System” in this section.

4.Disconnect the motor electrical plug from the blower motor assembly.

5.Remove the screws that secure the blower motor assembly to the in-line blower housing and set them aside.

6.Pull the spring clip to release the blower motor assembly. Remove the blower motor assembly from the housing and place it on a covered surface.

10

Page 10
Image 10
KitchenAid LI3ZBC/W10331009C Install Range Hood In-Line External Type Blower Motor, Prepare the In-line Blower System