Electrical Connection Inside Range Hood Between
1. | With the range hood mounted (see the “Install Range Hood” |
| section), locate the wiring cable connector inside the range |
| hood. |
2. | Connect the |
| |
| from the range hood. |
3. | Locate the terminal box inside the range hood and install a |
| ¹⁄₂" (1.3 cm) UL listed or CSA approved strain relief (see |
| “Complete Preparation” in the “Prepare Location” section). |
A. UL listed or CSA approved ¹⁄₂" F. Blue wires
(1.3 cm) wiring conduit | G. Gray wires |
B. UL listed wire connectors | H. Green (or yellow/green) |
C. Black wires | and green/yellow wires |
D. White wires | I. Motor electrical plug cable |
E. Red wires |
|
3. | Use UL listed wire connectors and connect the black wires |
| (C) together. |
4. | Use UL listed wire connectors and connect the white wires |
| (D) together. |
5. | Use UL listed wire connectors and connect the red wires (E) |
| together. |
6. | Use UL listed wire connectors and connect the blue wires (F) |
| together. |
4. | Run the wire ends from the |
| through the ¹⁄₂" (1.3 cm) strain relief, leaving enough wire |
| length to make the wiring connections. Tighten the strain |
| relief screws. |
5. | Connect the wires from the |
| wires from the wiring conduit inside the range hood terminal |
| box. |
6. | Connect the same color wires to each other (black to black, |
| white to white, etc.) using UL listed wire connectors. |
| NOTE: Connect the green (or green/yellow) ground wire from |
| the wiring conduit to the green (or bare) ground wire from the |
| home power supply using UL listed wire connectors (see the |
| “Make Electrical Power Supply Connection to Range Hood” |
| section). |
7. Use UL listed wire connectors and connect the gray wires (G) |
together. |
WARNING
Electrical Shock Hazard
B
A
C
D
E
F
G
H
Electrically ground blower.
Connect ground wire to green and yellow ground wire in terminal box.
Failure to do so can result in death or electrical shock.
8.Connect the green (or yellow/green) ground wire to the green/yellow ground wire (H) in the terminal box using UL listed wire connectors.
9.Reinstall the
10.Reinstall the front cover of the
| I |
A. UL listed or CSA approved | E. Red wires |
¹⁄₂" (1.3 cm) wiring conduit | F. Blue wires |
B. UL listed wire connectors | G. Gray wires |
C. Black wires | H. Green (or green/yellow) wire |
D. White wires | I. |
7.Go to “Make Electrical Power Supply Connection to Range Hood” section.
12