Electrical Connection Inside Range Hood Between In-line Blower System and Range Hood

1.

With the range hood mounted (see the “Install Range Hood”

 

section), locate the wiring cable connector inside the range

 

hood.

2.

Connect the 6-wire connector assembly supplied with the

 

in-line blower motor system to the mating cable connector

 

from the range hood.

3.

Locate the terminal box inside the range hood and install a

 

¹⁄₂" (1.3 cm) UL listed or CSA approved strain relief (see

 

“Complete Preparation” in the “Prepare Location” section).

A. UL listed or CSA approved ¹⁄₂" F. Blue wires

(1.3 cm) wiring conduit

G. Gray wires

B. UL listed wire connectors

H. Green (or yellow/green)

C. Black wires

and green/yellow wires

D. White wires

I. Motor electrical plug cable

E. Red wires

 

3.

Use UL listed wire connectors and connect the black wires

 

(C) together.

4.

Use UL listed wire connectors and connect the white wires

 

(D) together.

5.

Use UL listed wire connectors and connect the red wires (E)

 

together.

6.

Use UL listed wire connectors and connect the blue wires (F)

 

together.

4.

Run the wire ends from the 6-wire connector assembly

 

through the ¹⁄₂" (1.3 cm) strain relief, leaving enough wire

 

length to make the wiring connections. Tighten the strain

 

relief screws.

5.

Connect the wires from the 6-wire connector assembly to the

 

wires from the wiring conduit inside the range hood terminal

 

box.

6.

Connect the same color wires to each other (black to black,

 

white to white, etc.) using UL listed wire connectors.

 

NOTE: Connect the green (or green/yellow) ground wire from

 

the wiring conduit to the green (or bare) ground wire from the

 

home power supply using UL listed wire connectors (see the

 

“Make Electrical Power Supply Connection to Range Hood”

 

section).

7. Use UL listed wire connectors and connect the gray wires (G)

together.

WARNING

Electrical Shock Hazard

B

A

C

D

E

F

G

H

Electrically ground blower.

Connect ground wire to green and yellow ground wire in terminal box.

Failure to do so can result in death or electrical shock.

8.Connect the green (or yellow/green) ground wire to the green/yellow ground wire (H) in the terminal box using UL listed wire connectors.

9.Reinstall the in-line blower terminal box cover and screw.

10.Reinstall the front cover of the in-line blower housing and secure it with 10 mounting screws.

 

I

A. UL listed or CSA approved

E. Red wires

¹⁄₂" (1.3 cm) wiring conduit

F. Blue wires

B. UL listed wire connectors

G. Gray wires

C. Black wires

H. Green (or green/yellow) wire

D. White wires

I. 6-wire connector assembly

7.Go to “Make Electrical Power Supply Connection to Range Hood” section.

12

Page 12