Klark Teknik DN530 specifications Interfacing with the console, Using The Gate, Operator Manual

Models: DN530

1 56
Download 56 pages 21.93 Kb
Page 36
Image 36
Interfacing with the console

Chapter 7: Using The Gate

Interfacing with the console

The DN530 is optimised for use at line level, therefore to gate a mic, the input to the DN530 has to be taken from the console, preferably from the channel insert point send. The output from the DN530 comes back to the channel insert return. By connecting the DN530 at this position in the signal chain, its operation is unaffected by the use of any of the console controls, except input gain.

DN530 (rear panel)

Female XLR

connector

Mic

Channel insert point

Input

 

 

 

Send

Return

Mic inputs

Male XLR connector

Output

Console

An alternative is to connect to the group insert point of the console. This is useful when many inputs are mixed down to a smaller number of outputs. A given number of gates can achieve a greater coverage.

 

DN530

24

Operator Manual

Page 36
Image 36