Chapter 5: Rear Panel
Mains IEC socket
Fuse drawer

Chapter 5: Rear Panel

The rear panel of the DN530 (shown below) has three main connector sections: mains input, solo bus and the four channels.

Mains input

Solo bus

Four channels

Mains input

The mains input section has a mains IEC socket, below which is a fuse drawer. Printed to the right are mains supply voltage and fuse details.

The mains input is an auto-voltage sensing switch mode power supply that operates where normal mains voltage is in the range 100V AC to 240V AC.

The fuse drawer houses the mains fuse at the rear of a two-compartment drawer. The front compartment

provides room for a spare. Always replace the mains fuse with one of the same type and rating, as printed to the right of the fuse drawer.

Channels

There are four similar channel sections on the rear of the DN530. Each section comprises an input and an output XLR chassis connector, and a 1/4” TRS connector. These are used for connecting to external line level signals, such as a mixing console’s insert connections.

External

sidechain input (1/4” TRS jack)

Mains inputChannelsManual backgroundManual backgroundManual backgroundManual backgroundInput (female Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundXLR connector)

Output

(male XLR connector)