Knoll Systems MVP64A MR60 keypad functions, RJ45 plug function identification, 12 34, Outputs

Models: MVP64A

1 8
Download 8 pages 5.57 Kb
Page 8
Image 8
MVP64a Rear Panel

MVP64a Rear Panel

Source Inputs

 

Outputs

 

 

 

 

 

1

2

3

4

 

 

 

L

 

 

A1L+

A1L-

A2L-

A2L+

 

 

 

 

 

 

R

 

 

A1R+

A1R-

A2R-

A2R+

 

 

 

 

 

 

Note 1: Ideal speaker impedance is 6-8 ohms. When using 4 ohm speakers, individual channels may occasionally shutdown due to protection system.

Outputs

A3L+ A3L- B1L- B1L+

A3R+ A3R- B1R- B1R+

AC120V

 

 

234

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outputs

B2L+ B2L- B3L- B3L+

B2R+ B2R- B3R- B3R+

 

 

Room A1

 

 

Room A2

 

IR Emitters

 

 

 

Room A3

Room B1

Data

 

TrebleBassBalance

Treble Bass Balance

4/in 3 2 1

 

TrebleBassBalance Treble Bass Balance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To Keypads

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FD FC FB FA TOFF TON TRIG GND

Room A1

Room A2

Room A3

Room B1

Room B2

Room B3

 

 

 

Room B2

Room B3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Treble Bass Balance Treble Bass Balance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RJ45 plug function identification

MR60 keypad functions

ground

ground

comm

not

 

2

used

 

 

Each RJ45 connector uses 4 wires from MR60 to MVP64a for power, communications and IR. 3 are common, 12VDC, GND (either) and IR.

12

34

Infrared receiver

Four source selection (this room and whole house) and four function selection buttons

Three bar volume level

indicators, blinks at min or max

comm

12 VDC infrared

comm

3

 

1

1 is uniqure 2-way comm (1, 2 or 3) Comm1 goes to keypad slot A1 or B1 Comm2 goes to keypad slot A2 or B2 Comm3 goes to keypad slot A3 or B3

FNC MUTE

DN UP

OFF

Mute button

Function select button

Volume up and down

(this room only or whole house when FNC selected)

Shut off this room only or

whole house off button (also blinks when remote control signal detected)

RJ45 plug color and pair wiring guide

comm 1 brown white/brown orange white/blue blue white/orange green

not used white/green

Page 8
Image 8
Knoll Systems MVP64A MR60 keypad functions, RJ45 plug function identification, 12 34, MVP64a Rear Panel, Source Inputs