STAND ALONE INSTALLATION
***This installation only applies if installing with the CH1120DC duct cover.
Preparation before Installation
NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING.
•Decide the location of the venting pipe from the hood to the outside. (Figure 8)
•A straight, short vent run will allow the hood to perform more efficiently.
•Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood.
•Temporarily wire the hood to test for proper operation before installing.
•Important: Peel protective film off the hood and duct covers, if any.
•Use duct tape to seal joints between pipe sections.
•If necessary, prepare back wall frame with cross framing lumber for secure installation.
•Using references in TABLE 2 and measurements on pages
Figure 8
Figure 9
Hood Preparation before
Installation
•If necessary, attach two rubber stands (provided) with 3M adhesive tapes
(provided) to the back corners of the hood.
•Attach the outer duct
•Attach the
Hood Installation
Figure 10
Figure 11
CAUTION: If moving the cooking range to install the hood is necessary, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE.