Kobe Range Hoods CH7648SQB Ductwork Installation, Wiring to Power Supply, Safety Warning

Models: CH7630SQB CH7636SQB CH7648SQB CH7642SQB

1 35
Download 35 pages 41.96 Kb
Page 9
Image 9
 CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING.

4.Draw electrical wires through cabinet access opening.

5.From inside of the hood, place screw (not provided) into the exact center of each knockout hole and secure to cabinet bottom. Once all mounting screws are in place,

finish tightening screws until secure.

Ductwork Installation CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING.

6.For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure installation, use as many mounting holes as needed to secure from the inside of hood (screws not provided).

Figure 4

Figure 5

Ductwork Installation

7. Use 7” round steel pipe (follow building codes in your area) to connect the exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 4.

Wiring to Power Supply

Figure 6

SAFETY WARNING

RISK OF ELECTRICAL SHOCK. THIS

RANGE HOOD MUST BE PROPERLY

GROUNDED. MAKE SURE THIS IS DONE BY

QUALIFIED ELECTRICIAN IN ACCORDANCE

WITH ALL APPLICABLE NATIONAL AND

LOCAL ELECTRICAL CODES. BEFORE

CONNECTING WIRES, SWITCH POWER OFF

AT SERVICE PANEL AND LOCK SERVICE

PANEL TO PREVENT POWER FROM BEING

SWITCHED ON ACCIDENTALLY.

8.Connect the electrical wires.

-Connect three wires (black, white and green) to house wires and cap with wire connectors. Connect according to color: black to black, white to white, and green to green as shown in Figure 5.

-Store wires in the wiring box.

7

Page 9
Image 9
Kobe Range Hoods CH7648SQB Ductwork Installation, Wiring to Power Supply, Safety Warning, Switched On Accidentally