Figure 3

2.NOTE: Be careful when using electrical screwdriver, damage on the hood may oc Unscrew the six screws on the bottom casing. Remove the bottom casing as show Figure 4. If necessary, arrange the electrical wire to run through the 1￿ dia the hood.

3.Using references on Table 1 and measurements on page 15, center the hood in pl beneath the cabinet and flush with the front of the cabinet. Refer to Figure

Figure 4

4.Draw electrical wires through cabinet access opening

5.Place screws (not provided) into the exact center of each knockout hole. Make screws are in place before tightening screws. CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING.

Ductwork Installation

6.Use aluminum or steel pipe to connect the plastic exhaust on the hood to the d above. Use duct tape to make all joints secure and air tight.

Wiring to Power Supply

SAFETY WARNING

RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.

6

Page 8
Image 8
Kobe Range Hoods RA3830S, RA3836S installation instructions Safety Warning