Kobe Range Hoods RA3836SQD, RA3830SQD manual Stand Alone Installation, Safety Warning

Models: RA3836SQD RA3830SQD

1 23
Download 23 pages 15.88 Kb
Page 9
Image 9
STAND ALONE INSTALLATION

STAND ALONE INSTALLATION

***This installation only applies with the purchase of an optional duct cover (Mod

Manual backgroundSAFETY WARNING

HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.

Preparation before installation

-Temporarily wire the hood to test for proper operation before installing.

-Peel protective film off the hood and the duct cover (if any).

-If necessary, prepare back wall frame with cross framing lumber for secure i Using references on Table 2 and measurements on page 14, decide the level of lumber. Refer to Figure 5.

Hood Installation

CAUTION: If required to move the cooking range to install the hood, turn off the p electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE.

1.Remove the five screws at the center of the hood top. Use the five screws to plastic plate onto the hood as shown in Figure 6. NOTE: Disregard the hole t plastic plate.

2.If necessary, attach two rubber stands (provided) withscrewstwo (4x8(provided)mm) to the back of the hood.

Figure 5

3.Attach the hood-mounting bracket to the back of the hood with six (3/16 x 3/8 (provided) as shown in Figure 7.

4.Use the references on Table 2 and the measurements on page 14 to decide the le the hood. Position two mounting screws (not provided) on the wall, leaving 1/ from the wall. Refer to Figure 8.

7

Page 9
Image 9
Kobe Range Hoods RA3836SQD, RA3830SQD manual Stand Alone Installation, Safety Warning