Possible problems during operation

3UREOHP

 

3RVVLEOHUHDVRQV

 

+HOS

 

 

 

After switching on, the projector is not

Fuse (primary or secondary) blown.

Check fuse and possibly replace it.

operable. No defect is indicated by the red

 

 

For UK users: Check 13 A plug fuse also.

LED.

 

 

 

 

 

 

 

EKTAPRO 7020/9020: After switching on,

The projector is in "silent mode" (no

Press transport button and the projector will leave the silent mode (see.

the tray is moved (to 0-position) and the

defect).

page 24).

projector is switched off.

 

 

 

 

 

 

 

 

Red LED is flashing, and all functions

Projector drive system failure (tray

1.

Switch off projector; lift off slide tray; remove slide from the slide

are blocked (after switching-on or during

transportation, slide lift):

gate; rotate the base plate until it locks in position; replace the tray and

operation).

1.

Jammed slide in the slide gate.

switch on the projector.

 

2.

Slide tray base plate not in the zero

2.

Switch off projector; lift off slide tray, rotate the base plate until it

 

position.

locks in position; replace tray and switch on the projector.

 

3.

Slide tray base plate bent.

 

 

 

 

 

3.

Use a new slide tray.

 

4.Tray setting switch is not set correctly!

 

 

 

 

 

4.

Switch off projector; lift off slide tray, rotate the base plate until it

 

 

 

locks in position; set tray setting switch to correct position (see page 24);

 

 

 

replace tray and switch on the projector.

 

 

 

 

 

Image can’t be focused by focus buttons.

1.

Lens mount was not set to its default

1.

Press focus buttons to move lens mount to its default setting. Focus the

 

position.

image as indicated in the manual.

 

2.

Slide is distorted

2.

Use glass mounted slides.

 

3.

Slide mount is defective.

3.

Replace slide mount.

 

 

 

The tray cannot be fit on the tray transport

Tray transport ring not in zero position.

- Hold slide change buttons depressed till tray stops in zero-position or

ring

 

 

- switch projector off and then on again.

 

 

 

The tray cannot be moved.

Tray has not been placed correctly on the

Lift off the tray; switch projector on and then off again and then replace

 

transport ring.

tray.

 

 

 

Slides are one-sided illuminated.

Condensor out of position.

Switch off the projector; pull out the lamp module and let it cool down;

 

 

 

check that the condensor is correctly seated and push back into position if

 

 

 

necessary.

 

 

 

 

 

Fan runs but lamp is switched off.

1.

Lamp failure

1.

Refer to page 32

 

2.

Lamp module is not properly fixed.

2.

Refer to page 32

 

 

 

 

 

Even if autofocus is switched on, the

1.

Lens mount was not set to its default

1.

Switch autofocus off, move the lens mount to its middle position (s.

image is not in focus.

position.

page 26, switch on the autofocus and focus the image.

 

2.

Slide is distorted.

2.

Use glass mounted slides.

 

3.

Slide mount is defective.

3.

Replace slide mount.

 

4.

Slide in the 0-compartment of the tray

4.

Remove slide from the 0-compartment. (If necessary, further

 

 

 

information can be requested from Kodak).

 

 

 

After switching on the EKTAPRO 9020

Timer and the switch for slide tray zeroing

Switch off timer and/or switch for slide tray zeroing.

Slide Projector the tray is permanently

is switched on.

 

 

transported from the 0-position to the 1-

 

 

 

 

position and vice versa.

 

 

 

 

 

 

 

 

 

Note: If none of the faults listed above caused the problem, please contact your KODAK audiovisual products dealer.

34

Page 17
Image 17