8. ADJUSTMENTS

8. ADJUSTMENTS

M￿XIMUM W￿TER

TEMPER￿TURE ￿DJUSTMENT

Remove the handle and face plate from the valve, if installed.

Turn the valve stem fully clockwise to get maximum hot water flow.

To adjust the maximum temperature, slide the stem

O!ring out of groove and part way up valve stem. Move the upper limit stop ring part way up the valve stem. Rotate the valve stem until the desired maximum water temperature is reached. Rotate lower limit stop ring until it contacts the tab. Slide the upper limit stop down the valve stem to engage the lower limit stop. Slide the O!ring into the valve stem groove.

Rotate the valve stem counterclockwise to shut the water off. Reinstall the handle and face plate.

Tab

Lower Limit

Stop

Groove

Upper Limit

Stop

Valve

Stem

O$Ring