Kohler CFI230G Commissioning, General, Set the Maximum Temperature, Temperature Selection oC

Models: CFI230G

1 14
Download 14 pages 25.65 Kb
Page 10
Image 10
If the any further adjustment is required to make

Check the wall channel and jamb is vertical. Loosen screws ‘A’ to adjust from side to side.

Re-tighten screws

A

STEP

18

If the any further adjustment is required to make

the glass panel vertical turn the 4 screws ‘D’

until the panel is in the correct position

D

STEP

20

10 CFI230G

The edge of the glass should fit against the end of the slot in the tray ‘B’. To adjust the glass loosen the 4 screws ‘C’ and move the panel until it is the correct postion. Re-tighten screws

C

Check end of glass is vertical

B

STEP

19

Measure the distance of the glass between

the wall jamb and the tray ‘A’. Cut the

splashguard to size cutting at the wall jamb end.

Fit the splashguard to the bottom of the glass

A

STEP

21

COMMISSIONING

1.General

1.1.Turn on the water supply to the Digital Mixer.

1.2.Check for leaks over the complete system.

1.3.Turn on the electrical supply to the Digital Mixer.

For the Pumped Version with the Slider Rail Shower System, pump priming can be helped by removing the handset and lowering the end of the hose into the shower tray.

2. Set the Maximum Temperature

Note! The maximum temperature of the unit can only be set when the unit has not been used for a period of 10 minutes.

2.1.Temperature Selection - Set the temperature control knob to the desired position, as per the table below.

Temperature Control

Temperature Selection oC

Knob Position

 

 

 

1

Factory Set 45

 

 

2

39

 

 

3

40

 

 

4

42

 

 

5

43

 

 

6

44

 

 

7

45

 

 

7.5

46

 

 

8

47

 

 

9

48

 

 

2.2.Enabling - Press and momentarily hold the Warm Up and High keys at the same time. Release the push-button and reselect within 2 seconds. The two keys will flash twice and beep three times to confirm the selection is successful.

3.Lock Mode

Note! Allows you to lock the unit during operation.

3.1.Selection - Press and momentarily hold the Warm Up and Medium keys at the same time. The two keys will flash twice and beep three times to confirm the selection is successful.

3.2.Operation - This mode locks out all the keys except the Warm Up/Off key. It also locks the temperature control knob. Once selected it is only possible to turn the unit OFF.

Selecting Warm Up/Off and Medium at the same time again, cancels the lock mode.

CFI230G 19