Kohler K-10104 manual Troubleshooting, Complete the Installation cont, Symptoms, Probable, Causes

Models: K-10103 K-10104

1 44
Download 44 pages 62.88 Kb
Page 10
Image 10
Complete the Installation (cont.)

Complete the Installation (cont.)

Place the handle in the vertical position, as shown.

Rotate the handle clockwise, then reposition the handle at the 2 o’clock position.

For hot and cold water supply installations: Rotate the handle as

needed to achieve the desired water temperature.

For tempered or filtered water installations: Turn the handle

counterclockwise to the full cold position.

Secure the cover and handle to the valve with two screws (provided).

7. Troubleshooting

Symptoms

Probable

Recommended Action

 

Causes

 

 

1. No water

A.

There is a

A.

Remove the valve cover and

flow.

 

loose

 

check the connections from the

 

 

connection.

 

battery to the solenoid and

 

 

 

 

from the battery holder to the

 

 

 

 

sensor. Make sure that the

 

 

 

 

connector arrows are aligned

 

 

 

 

and that the connection is

 

 

 

 

secure.

 

B.

The

B.

Confirm the supply stops are in

 

 

supply

 

the ONposition.

 

 

stops are

 

 

 

 

in the

 

 

 

 

OFF

 

 

 

 

position.

 

 

 

C.

The

C. Remove the cover and inspect

 

 

wires/cables

 

the wires/cables for cuts or

 

 

are

 

damage. If the wires are cut or

 

 

pinched or

 

damaged, order a new

 

 

damaged.

 

solenoid, sensor assembly,

 

 

 

 

sensor extension cable, or

 

 

 

 

battery holder. Do not pinch or

 

 

 

 

damage the wires during

 

 

 

 

reassembly.

 

 

 

 

 

1056542-2-B

10

Kohler Co.

Page 10
Image 10
Kohler K-10104, K-10103 Troubleshooting, Complete the Installation cont, Symptoms, Probable, Recommended Action, Causes