Kohler K-10103, K-10104 manual Troubleshooting cont, Symptoms, Probable, Recommended Action, Causes

Models: K-10103 K-10104

1 44
Download 44 pages 62.88 Kb
Page 11
Image 11
Troubleshooting (cont.)

Troubleshooting (cont.)

 

 

 

 

 

 

Symptoms

Probable

 

Recommended Action

 

Causes

 

 

 

 

D. There is

 

D. Remove the cover and check

 

 

water

 

 

for corrosion on the

 

 

leakage on

 

 

connections between the

 

 

electrical

 

 

battery to solenoid and the

 

 

components

 

 

battery holder to the sensor. If

 

 

or

 

 

possible, clean the terminals. If

 

 

connectors.

 

 

unable to repair the connection,

 

 

 

 

 

order a new sensor assembly,

 

 

 

 

 

battery holder, or solenoid

 

 

 

 

 

assembly, as required. Inspect

 

 

 

 

 

the gasket between the valve

 

 

 

 

 

body and spout hose for cuts,

 

 

 

 

 

debris, etc. If the gasket is

 

 

 

 

 

damaged, order a new gasket.

 

 

 

 

 

The origin of the leak must be

 

 

 

 

 

investigated and repaired.

 

E.

The

 

E.

Remove the cover and replace

 

 

battery life

 

 

the battery. The faucet requires

 

 

has

 

 

a standard 2CR5 6 V lithium

 

 

expired.

 

 

battery. This item is not

 

 

 

 

 

available from Kohler Co., but

 

 

 

 

 

can be purchased at retail

 

 

 

 

 

stores.

 

F.

Sensor

 

F.

Wipe the sensor eyes with a

 

 

eyes are

 

 

damp soft cloth. Wipe dry with

 

 

dirty.

 

 

a dry soft cloth.

 

G. Supply

 

G. Verify that the water supply is

 

 

pressure is

 

 

turned on and that pressure is

 

 

low.

 

 

at least 20 psi (137 kPa).

 

H. Incorrect

 

H. Verify that the faucet is

 

 

installation.

 

 

mounted flat to the deck

 

 

 

 

 

surface and that the sensor eyes

 

 

 

 

 

are aligned to the user area.

 

I.

The filters

I.

Refer to the Service the Filters

 

 

are

 

 

section of the Homeowners

 

 

plugged.

 

 

Guide.

 

J.

The

 

J.

Remove the aerator and clean.

 

 

aerator is

 

 

For calcium/mineral deposits,

 

 

plugged.

 

 

soak the plastic insert in a 50:50

 

 

 

 

 

mix of water and vinegar. Soak

 

 

 

 

 

only the plastic insert.

 

K.

Sensor

 

K.

Replace the sensor assembly.

 

 

eyes are

 

 

 

 

 

scratched.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Kohler Co.

 

11

 

1056542-2-B

Page 11
Image 11
Kohler K-10103, K-10104 manual Troubleshooting cont, Symptoms, Probable, Recommended Action, Causes