![4. Water Temperature Adjustments](/images/new-backgrounds/40145/4014513x1.webp)
Handle
Setscrew
Bonnet
Stop | Valve Stem |
Tab | Top Disc |
| |
Mounting Nut | Indexer |
| Splines |
4. Water Temperature Adjustments
NOTE: Prior to adjustment, make sure the handle is in the maximum hot position.
Remove the setscrew, handle, and bonnet.
Turn on the water to the maximum temperature by pushing the valve stem up and turning it clockwise.
Mark the current position of the temperature stop tab (top edge) on the mounting nut with a marker or pencil.
Lift the indexer and top disc just enough to clear the valve splines and to allow rotation.
NOTE: Each spline notch is an average 9.5_F (5.3_C) change in temperature.
Turn the indexer, top disc, and valve stem counterclockwise until the desired temperature is achieved.
Reinstall the indexer and top disc to the valve, making sure the top disc is snapped fully into the indexer.
Turn off the water by pulling the valve stem down.
Reinstall the bonnet, handle, and setscrew.
Kohler Co. | 7 |