4. Water Temperature Adjustments

Handle

Setscrew

Bonnet

Stop

Valve Stem

Tab

Top Disc

 

Mounting Nut

Indexer

 

Splines

4. Water Temperature Adjustments

NOTE: Prior to adjustment, make sure the handle is in the maximum hot position.

Remove the setscrew, handle, and bonnet.

Turn on the water to the maximum temperature by pushing the valve stem up and turning it clockwise.

Mark the current position of the temperature stop tab (top edge) on the mounting nut with a marker or pencil.

Lift the indexer and top disc just enough to clear the valve splines and to allow rotation.

NOTE: Each spline notch is an average 9.5_F (5.3_C) change in temperature.

Turn the indexer, top disc, and valve stem counterclockwise until the desired temperature is achieved.

Reinstall the indexer and top disc to the valve, making sure the top disc is snapped fully into the indexer.

Turn off the water by pulling the valve stem down.

Reinstall the bonnet, handle, and setscrew.