5.CHECK WATER LEVEL | 5. |
Turn on water supply check for leaks. If necessary, adjust |
|
black float adjustment clip, and sliding float up or down on |
|
metal float rod until water level at marked water line 5A . | 5A |
Float
Float
Adjustment clip
5A
190
|
|
| 5B |
| Fig. #5 |
|
|
| 5 |
|
|
Make sure the arrow on the green float on the white flush |
|
| 2 |
valve is secure and pointing to #2. (Fig. 5B ) | ( | 5B | ) |
|
|
|
|
6. ADJUST OVERFLOW HEIGHT (If necessary) | 6. | ( | ) |
Adjust overflow tube so that the top is 20mm above the |
|
| 20mm |
waterline. Push locking mechanism to the side and adjust |
|
|
|
tube height. Push locking mechanism back into position to |
| 6 |
|
lock tube height. See Fig.#6. |
|
|
|
1 | maxi | 2 |
|
Fig. #6 6