Kohler KT6908 Water Temperature Adjustment, Standard High Flow Valve Valve, Setscrew Tab, Collar

Models: KT6908 KT6910 KT6913

1 20
Download 20 pages 61.27 Kb
Page 5
Image 5
Standard

Standard

High Flow Valve

Valve

Tab

Setscrew

Tab

Collar

Valve

Stem

Collar

Setscrew

Valve Label

O-Ring

3. Water Temperature Adjustment

CAUTION: Risk of personal injury. To eliminate the risk of scalding, the water temperature should never be set above 120°F (49°C).

NOTE: Do not remove the O-ring and collar at this time. Removing the O-ring and collar will change the factory setting for the maximum water temperature.

Turn the valve clockwise to the full open position and let the hot water run for several minutes. Position a thermometer in the water stream and check the temperature.

For minor water temperature changes, adjust the setscrew, and recheck the water temperature.

For major water temperature changes, remove the O-ring and collar from the valve stem. Slowly rotate the valve stem until the desired maximum water temperature is reached.

Reinstall the collar on the valve stem with the setscrew against the side of the tab.

Reinstall the O-ring, rotate the valve stem counterclockwise to shut the water off.

Recheck the water temperature.

Complete the information on the valve label (if supplied).

Kohler Co.

5

114487-2-CC

Page 5
Image 5
Kohler KT6908 Water Temperature Adjustment, Standard High Flow Valve Valve, Setscrew Tab, Collar, Valve Label, O-Ring