QProduct features

This appliance has been designed for charging a variety of SLA batteries (sealed lead acid batteries), as mainly used in cars, motorbikes and several other vehicles. They may be of types e.g. WET (with liquid electrolyte), GEL (with mit gel-type electolyte) or AGM (absorbed glass mat) batteries. Their capacity ranges from 12 V / 1.2 Ah to 12 V / 120 Ah.

A special design of the appliance (also named „three-phase-charging strategy“) enables the recharg- ing of the batttery to almost 100 % of its original capacity. Furthermore, a long-term connection of the battery to the charging station can take place to keep the battery in optimal condition when not in use, without it being damaged in the process.

QOperation

QPreparing for use

mCaution! Danger of electric shock! Only install, maintain and service the appliance when it is disconnected form the mains!

Working safely

jWhen putting the appliance into operation, select a suitable place to do so.

jTake your time when carefully preparing to put the appliance into operation. Put all compoments and any additionally required tools or materials well arranged and within easy reach.

jAlways be alert and pay attention to what you are doing. Be sensible when working and do not operate the charging station if you lack the ability to concentrate or do not feel well.

QConnection

jBefore starting the charging or discharging procedure on a permanently installed battery in a vehicle, first disconnect the minus pole con-

Safety / Operation

necting cable (black) of the vehicle from the minus pole of the battery. The minus pole of the battery is usually connected to the car body.

jThen disconect the plus pole connecting cable (red) of the vehicle from the plus pole of the battery.

jThen first connect the „+“ pole quick-contact clamp (red) 14 of the charging station to the plus pole („+“ pole) of the battery.

jConnect the „–“ pole quick-contact clamp (black) 15 to the „–“ pole of the battery.

jConnect the power cord 10 of the battery charging station to the socket oulet with earthing contact of the power supply.

QDisconnecting

jDisconnect the appliance from the power supply.

jDisconnect the „–“ pole quick-contact clamp (black) 15 from the „–“ pole of the battery.

jDisconnect the „+“ pole quick-contact clamp (red) 14 from the „+“ pole of the battery.

jReconnect the plus pole connecting cable of the vehicle to the plus pole of the battery.

jReconnect the minus pole connecting cable of the vehicle to the minus pole of the battery.

QSelect charging mode

For charging various batteries at different ambient temperatures you can choose between three different charging modes. Select the most efficient and suita- ble charging mode for charging the battery.

In comparison with conventional battery charging stations, this appliance has a special function for reusing an empty battery or rechargeable battery. You can recharge an empty battery / rechargeable battery. Safe charging is ensured by means of a protection function against incorrect connection and short circuiting. Due to the installed electronics, the charging station does not begin operation directly after connecting the battery, but only starts after a charging mode has been selected.

GB/IE/CY 9