15
4.6  Connecting the Wall Plates 
The wall plates should be connected to the corresponding inputs on the SV-551 
using the supplied or optional STP cables1 9 (see Section  ). The SV-301 has two 
RJ-45 CAT 5 connectors (one for DDC and one for PC (Video/Audio/Power (US 
version)), as Table 4 defines, and comes with two STP cables. The SV-302 has one 
RJ-45 CAT 5 connector (U.S. version) and comes with one STP cable. 
To connect the SV-301, as the example in Figure 3 illustrates (see also the 
separate color illustration referred to in Section  5.6): 
1.  Connect the computer graphics source (for example, a laptop) to the Computer In 
15-pin HD connector and to the unbalanced stereo Audio In 3.5mm mini jack on 
the front of the SV-301, for example, using a Kramer C-GMA/GMA cable (VGA 
HD15M +Audio jack to VGA HD15M +Audio jack)2
2.  On the rear of the SV-301, connect the RJ-45 CAT 5 connector marked: 
. 
 “DDC” to the DDC 1 INPUT on the SV-551 
 “PC” to the PC 1 INPUT on the SV-551 
Figure 3: Connecting the SV-301 to the SV-551 
1 There are two types of STP cable provided with SummitView™: CP-STP-50 (plenum-rated for the SummitView™ US) or C-STP-50 
(non-plenum for the SummitView™ Europe). Other STP cables can also be used. However, when using longer STP cables, image 
quality can be impaired 
2 Not supplied. The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com