15
4.6 Connecting the Wall Plates
The wall plates should be connected to the corresponding inputs on the SV-551
using the supplied or optional STP cables1 9 (see Section ). The SV-301 has two
RJ-45 CAT 5 connectors (one for DDC and one for PC (Video/Audio/Power (US
version)), as Table 4 defines, and comes with two STP cables. The SV-302 has one
RJ-45 CAT 5 connector (U.S. version) and comes with one STP cable.
To connect the SV-301, as the example in Figure 3 illustrates (see also the
separate color illustration referred to in Section 5.6):
1. Connect the computer graphics source (for example, a laptop) to the Computer In
15-pin HD connector and to the unbalanced stereo Audio In 3.5mm mini jack on
the front of the SV-301, for example, using a Kramer C-GMA/GMA cable (VGA
HD15M +Audio jack to VGA HD15M +Audio jack)2
2. On the rear of the SV-301, connect the RJ-45 CAT 5 connector marked:
.
DDCto the DDC 1 INPUT on the SV-551
PCto the PC 1 INPUT on the SV-551
Figure 3: Connecting the SV-301 to the SV-551
1 There are two types of STP cable provided with SummitView™: CP-STP-50 (plenum-rated for the SummitView™ US) or C-STP-50
(non-plenum for the SummitView™ Europe). Other STP cables can also be used. However, when using longer STP cables, image
quality can be impaired
2 Not supplied. The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com