Krell Industries KSA-200S, KSA-300S, KSA-100S manual Bias Level Meter, Operation

Models: KSA-100S KSA-300S KSA-200S

1 24
Download 24 pages 7.8 Kb
Page 15
Image 15
BIAS LEVEL METER

OPERATION

BIAS LEVEL METER

The KSAamplifiers utilize Sustained Plateau Biasing, a proprietary KRELL design. The Bias display meter on the front panel of the amplifier displays

which level of bias the amplifier is utilizing. Unlike sliding bias designs, Sustained Plateau Bias only changes level when the demand situation relative to input and source material changes. The signal passes through a section called an Anticipator circuit. Once the level of bias is determined by the Anticipator circuit, it automatically biases the output ~f the amplifier before the signal is passed through the output stage. The Anticipator circuit

is several times faster than the output stage itself. This technique insures all signal is passed through the amplifier in pure Class A operation. If the amplifier only requires a low level of Class A bias, the amplifier will bias itself

to use only the amount of Class A power necessary to the demand

parameters. Should the demand parameters exceed the bias level the amplifier is presently working under, the amplifier will increase its bias to the next level to allow all signal to come through in Class A operation. If the demand parameters are less then the bias level indicates for more than 15- 20 seconds, the amplifier will drop to the next lowest bias level.

The bias levels are indicated by appropriate LEDs in the faceplate meter display as they are activated.

Should the demand parameters reach a point at which the temperature of the external heatsink reaches approximately 80 degrees Celsius, the last two levels of bias 3 and 4 will be disabled until the heatsink temperature drops to a safe operating level. The overall output power of the amplifier is not changed when this occurs, only the amount of class A power. You will notice the LEDscorresponding to the top two levels of bias will not illuminate. The LEDs for levels 3 and 4.will come back on when the heatsink temperature is at safe operating levels. This temperature fluctuation will not harm the amplifier. It is provided for consumer safety in a home listening environ- ment.

PAGE 15

Page 15
Image 15
Krell Industries KSA-200S, KSA-300S, KSA-100S manual Bias Level Meter, Operation