KTI Networks KGS-2416 user manual RS-232 DB-9 Connector AC Line 100-240V 50/60 Hz

Models: KGS-2416

1 245
Download 245 pages 58.3 Kb
Page 25
Image 25

User Manual

2-1-4-1. Configuring the Management Agent of 8-Port TP + 16-Port SFP L2 Managed Gigabit Switch through the Serial RS-232 Port

To perform the configuration through RS-232 console port, the switch’s serial port must be directly connected to a DCE device, for example, a PC, through RS-232 cable with DB-9 connector. Next, run a terminal emulator with the default setting of the switch’s serial port. With this, you can communicate with the switch.

In the switch, RS-232 interface only supports baud rate 57.6k bps with 8 data bits, 1 stop bit, no parity check and no flow control.

RS-232 DB-9 Connector

AC Line 100-240V 50/60 Hz

RS-232

8-Port TP + 16-Port SFP L2 Managed Gigabit Switch Default IP Setting:

IP address = 192.168.1.1 Subnet Mask = 255.255.255.0 Default Gateway = 192.168.1.254

RS-232 cable with female

 

DB-9 connector at both ends

Fig. 2-7

Terminal or Terminal Emulator

To configure the switch, please follow the procedures below:

1.Find the RS-232 DB-9 cable with female DB-9 connector bundled. Normally, it just uses pins 2, 3 and 7. See also Appendix B for more details on Null Modem Cable Specifications.

2.Attaches the DB-9 female cable connector to the male serial RS-232 DB-9 connector on the switch.

3.Attaches the other end of the serial RS-232 DB-9 cable to PC’s serial port, running a terminal emulator supporting VT100/ANSI terminal with The switch’s serial port default settings. For example, Windows98/2000/XP HyperTerminal utility.

Note: The switch’s serial port default settings are listed as follows:

Baud rate

57600

Stop bits

1

Data bits

8

Parity

N

Flow control

none

4.When you complete the connection, then press <Enter> key. The login prompt will be shown on the screen. The default username and password are shown as below:

Username = admin

Password = admin

Publication date: January, 2006

Revision A2

17

Page 25
Image 25
KTI Networks KGS-2416 user manual RS-232 DB-9 Connector AC Line 100-240V 50/60 Hz