Kuppersbusch USA EKI 848.0 Electrical connection, Technical data, Start of operation, Dimensions

Models: EKI 807.2 EKI 848.0 EKI 607.2

1 17
Download 17 pages 44.97 Kb
Page 16
Image 16
Electrical connection

Instructions for assembly

Electrical connection

The electrical connection must be carried out by a quali- fied electrician who is authorised to carry out such work!

Statutory regulations and the connection specifications issued by the local power supply company must be strictly observed.

When connecting the appliance it must be ensured that there is a device which makes it possible to disconnect it from the mains at all poles with a contact opening width of at least 3 mm. Line-protecting switches, fuses or contactors are sui- table cut-out devices.

When connecting and repairing the appliance disconnect it from the electricity supply with one of these devices.

The earth wire must be sufficiently long so that if the strain relief fails, the live wires of the connecting cable are subjected to tension before the earth wire.

Any superfluous cable must be removed from the installation area beneath the appliance.

Make sure that the local mains voltage is the same as the voltage on the rating label.

To connect the appliance, unscrew the switchbox cover on the underside of the appliance to access the terminal block. After connecting the appliance, replace the cover and secure the connection cable with the strain relief clamp.

The connection cable must be at least H05 RR-F.

If the excess cable of this appliance is damaged, it has to be replaced by the manufacturer, the Customer Service of the manufacturer or by another qualified person in order to avoid putting persons at risk.

Full protection against accidental contact must be ensured on installation.

Attention! Incorrect connection may result in the power electronics unit being destroyed.

Power supply

Mains voltage: 400-415V 2N~, 50-60 Hz

Component rated voltage: 230 - 240V

Electrical connections

GB

Technical data

EKI 607

Dimensions

 

 

 

 

Hob Height/ Width/ Depth mm

45 x 589 x 519

Cooking zone

 

 

 

 

Front left

Ø cm / kW

21/ 2,3 (3,2)*

 

 

 

 

Back left

Ø cm / kW

14.5/ 1.4 (1.8)*

 

 

Back right

Ø cm / kW

18/ 1.85 (2,5)*

 

 

 

 

Front right

Ø cm / kW

14.5/ 1.4 (1.8)*

 

 

Hob, total

kW

7.4

 

 

 

 

 

 

 

* Power when the power boost function is activated

EKI 807

Dimensions

 

 

 

 

Hob Height/ Width/ Depth mm

45 x 779 x 519

Cooking zone

 

 

 

 

Front left

Ø cm / kW

26/ 2,4 (3,2)*

 

 

 

 

Back left

Ø cm / kW

14.5/ 1.4 (1.8)*

 

 

Back right

Ø cm / kW

18/ 1.85 (2.5)*

 

 

 

 

Front right

Ø cm / kW

18/ 1.85 (2.5)*

 

 

Hob, total

kW

7.4

 

 

 

 

 

 

 

* Power when the power boost function is activated

EKI 848

Dimensions

 

 

 

 

Hob Height/ Width/ Depth mm

45 x 779 x 519

Cooking zone

 

 

 

 

Front left

Ø cm / kW

26/ 2.4 (3.2)*

 

 

 

 

Back left

Ø cm / kW

14.5/ 1.4 (1.8)*

 

 

Back right

Ø cm / kW

18/ 1.85 (2.5)*

 

 

 

 

Front right

Ø cm / kW

18/ 1.85 (2.5)*

 

 

Hob, total

kW

7.4

 

 

 

 

 

 

 

* Power when the power boost function is activated

Start of operation

Once the hob has been installed and the power supply has been provided (mains connected) an automatic test of the controls will be carried out and information for Customer Service will be indicated.

Briefly wipe over the surface of the hob with a sponge and soapy water and then dry with a clean cloth.

33

Page 16
Image 16
Kuppersbusch USA EKI 848.0 Technical data, Start of operation, Power supply, Electrical connections, Dimensions