Activated charcoal filter (Recirculation version)

REPLACING THE ACTIVATED CHARCOAL FILTER

• This filter is not washable and cannot be regen- erated, and must be replaced approximately every four months of operation, or more frequently with heavy usage.

Remove the metal grease filters.

Remove the saturated activated carbon filter by releasing the fixing hooks.

Fit the new filter by hooking it into its seating.

Replace the metal grease filters.

Lighting

LIGHT REPLACEMENT

• 20 W halogen light.

• Remove the 2 Screws fixing the Lighting sup- port, and pull it out of from the Hood.

Extract the Lamp from the Support.

Replace with another of the same type, making

sure that the two pins are properly inserted in the lamp holder socket holes.

Replace the Support, fixing it in place with the two Screws removed as above.

FUSE REPLACEMENT

Fuse: model 5x20 5A time-delay

Remove the filters.

Remove the Screws fixing the fuseholder box.

Open the fuseholder (bayonet fixing).

Replace the fuse with another of the same type.

Replace the fuseholder box and the filters.