!To define exception condition parameters

VRS Getting Started Guide

Table 3. Action Types

Action Type

Description

 

 

Return Error

Pass error (without the image) to the host application.

 

 

Ignore Error

Accept image "as is," pass it to the host application, and resume the

 

scanning session.

 

 

Intervention

Open the Auto Resolve Manager in manual mode. As a result, the

 

user is presented a range of options for handling the error. See the

 

next section, Using the Auto Resolve Manager.

 

 

Auto Resolve

Opens the Auto Resolve Manager in automatic mode. As a result, the

 

scanner automatically attempts to retry the scan until the user

 

resolves an equipment or paper transport impediment, such as a loose

 

cable, paper jam, or out of paper condition. See the next section, Using

 

the Auto Resolve Manager.

 

 

Interactive

Opens the VRS Interactive Properties dialog box and displays the

 

image in the VRS Viewer, so that the user can apply new settings to

 

the current image. The dialog box opens to the tab that relates to the

 

warning condition. For example, if a Brightness Out of Range

 

warning occurs, the dialog box would open with the focus on the

 

Clarity tab, where the brightness setting can be adjusted.

 

 

!To define exception condition parameters

1 From the Windows taskbar, right-click on the VRS icon to open the VRS menu.

2 From the VRS menu, select Configure to open the VRS Administration Utility dialog box.

3Select one of the following tabs: a Warnings tab

The Warnings tab gives you options to set the threshold and response for exceptions related to image quality, as listed in Table 1 on page 14.

bErrors tab

The Errors tab gives you options to set the response to exceptions related to equipment conflicts and paper transport errors, as listed in Table 2 on page 17.

4Adjust the settings for each tab. a Warnings tab - Threshold

From the Warnings tab, you can type directly into the Threshold box, or click the arrows to select a new threshold setting. For more information about thresholds, see the section Warnings Tab on page 14.

bWarnings tab/Errors tab - Action

From the Warnings tab and the Errors tab, define a VRS response to each exception type by clicking in the Action box and selecting from the drop-down list. For details, see Action Options on page 17.

5Once you are satisfied with the settings, click Save.