Table 1 defines each status or alarm bit position.

Table 1: Status or alarm binary codes

Status or alarm

Bit position

Bit value and description

character

 

 

 

position

 

 

 

a or f

19

Not used

 

 

 

 

18

Not used

 

 

 

 

16 and 17

Remote control bits:

 

 

0:0 = Autoswitch/don’t care

 

 

0:1 = Channel A selected

 

 

1:0 = Channel B selected

 

 

1:1 = Not used

 

 

 

b or g

15 and 14

Front panel switch control bits:

 

 

0:0 = Autoswitch/don’t care

 

 

0:1 = Channel A selected

 

 

1:0 = Channel B selected

 

 

1:1 = Not used

 

 

 

 

 

13

0

= Channel A active input

 

 

1

= Channel B active input

 

 

 

 

 

12

1

= Cannot lock to input B

 

 

 

 

c or h

11

1

= Cannot lock to input A

 

 

 

 

 

10

1

= Autoswitch occurred

 

 

 

 

 

9

1

= Power supply 2 fault

 

 

 

 

 

8

1

= Power supply 1 fault

 

 

 

 

d or i

7

1

= output 8 failed

 

 

 

 

 

6

1

= output 7 failed

 

 

 

 

 

5

1

= output 6 failed

 

 

 

 

 

4

1

= output 5 failed

 

 

 

 

e or j

3

1

= output 4 failed

 

 

 

 

 

2

1

= output 3 failed

 

 

 

 

 

1

1

= output 2 failed

 

 

 

 

 

0

1

= output 1 failed

 

 

 

 