LCD Digital DGP2-641 Stay Arming, Instant Arming, Force Arming, Bypass Programming

Models: DGP2-641

1 28
Download 28 pages 12.83 Kb
Page 6
Image 6

3.3STAY ARMING

Stay arming will partially arm your system to permit you to remain in your home or office by arming the outer zones (perimeter) of the protected area (i.e. doors and windows).

1.Enter your [ACCESS CODE].

2.Press the [STAY] button.

3.If you have access to more than one area, select the area(s) you wish to Stay arm (refer to section 2.3 on page 5).

3.4INSTANT ARMING

This feature is the same as Stay arming except that there is no Entry Delay. Therefore, any armed zone that is breached will immediately generate an alarm.

1.Enter your [ACCESS CODE].

2.Press the [5] button.

3.If you have access to more than one area, select the area(s) you wish to Instant arm (refer to section 2.3 on page 5)

3.5FORCE ARMING

Force arming allows you to quickly arm your system when zones are open. However, once the open zone is closed, your system will then arm that zone as well.

1.Enter your [ACCESS CODE].

2.Press the [FORCE] button.

3.If you have access to more than one area, select the area(s) you wish to Force arm (refer to section 2.3 on page 5).

3.6BYPASS PROGRAMMING

You can bypass certain zones when you arm the protected area(s). When a zone is bypassed, it will be ignored the next time your system is armed. Once your area is disarmed, the system will unbypass the zone.

1.Enter your [ACCESS CODE].

2.Press the [BYP] button.

3.Enter the zone number (i.e. 01, 02,...48), or use the [S] and [T] buttons and press [BYP] once the zone you want to bypass appears on the screen. If “bypassed” does not appear on the screen and the keypad emits a Rejection Beep, you may not have access to bypass that zone.

4.Repeat step 3 until all zones you want to bypass have been selected.

5.Press the [ENTER] button to save and exit.

In order to bypass a zone, the following conditions must be met:

- The zone must have the Bypass option programmed by the installer.

- Your User Access Code must be programmed to enable the Bypass option.

-Your User Access Code must have access to the zone’s Area Assignment.

-The zone’s area must be disarmed before the zone can be bypassed.

Fire Zones cannot be bypassed.

3.6.1BYPASS RECALL

Bypass Recall reinstates the zones that were bypassed the last time your system was armed.

1.Enter your [ACCESS CODE].

2.Press the [BYP] button.

3.Press the [MEM] button. Zones bypassed the last time your system was armed are bypassed.

4.Press the [ENTER] button to save and exit.

6 System Manager’s Manual