Switching off the beep
Press and hold simultaneously for 5 seconds:
The beep is switched off.
To reactivate it, press and hold for 5 seconds.
Appendix
Display Notices
All display notices are either displayed with or "Error". The following errors can be corrected.
| Cause | Correction |
204 | Calculation error | Repeat procedure |
252 | Temperature too | Let device cool down. |
| high |
|
253 | Temperature too | Warm device up |
| low |
|
255 | Received signal too | Use a target plate |
| weak, time for a |
|
| measurement too |
|
| long. |
|
256 | Received signal too | Use target plate (gray |
| strong | side) |
257Faulty measure- Use target plate (brown
ment, too much | side) |
background light |
|
Cause | Correction | EN |
258Outside of the range Select measurement
| of measurement | distance within the |
|
| range of measurement |
|
|
|
Error | Cause | Correction |
Error | Hardware error | Should this message |
|
| remain active after |
|
| switching the instru- |
|
| ment off and on several |
|
| times, please contact |
|
| the dealerhip. |
Technical Specifications
Range | 0.05 m to 60 m* |
| (0.16 ft to 197 ft*) |
Measuring accuracy (2 σ) | typically ± 0.06 in** |
Smallest unit displayed | 1 mm (1/ in) |
| 16 |
Laser class | 2 |
Laser type | 635 nm, < 1 mW |
Protection against | IP 54, |
splashes and dust | |
Autom. power off: | after 90 s |
Laser | |
Instrument | after 180 s |
Illumination | 9 |
Folding out endpiece | 9 |
Battery life, | up to |
Type 2 x AAA | 5 000 measurements |
Leica DISTO™ D2 762960 en
9