Image 21

 

Cause

Remedy

252

Temperature too

Cool down instrument

 

high

 

253

Temperature too

Warm up instrument

 

low

 

255

Receiver signal too

Use target plate

 

weak, measurement

 

 

time too long,

 

 

distance > 100 m

 

256

Received signal too

Target too reflective

 

strong

(use target plate)

257Wrong measure- Darkentarget(measure

 

ment, background

in different lighting

 

brightness too high

conditions)

260

Laser beam inter-

Repeat measurement

 

rupted

 

 

 

 

Error

Cause

Remedy

Error

Hardware error

Switch on/off the

 

 

device several times. If

 

 

the symbol still

 

 

appears, then your

 

 

instrument is defective.

 

 

Please call your dealer

 

 

for assistance.

Technical data

Power Range

0.05 m to 100 m

Technology™:

Range (use target plate

2 in. to 325 ft

from about 80m/260ft)

 

Smallest unit displayed

0.1 mm/ 1/32nd

Distance measurement

9

Minimum/maximum

 

measurement, Continuous

9

measurement

 

Area/volume calculation of

9

room data

 

Addition / subtraction

9

Indirect measurement

9

using Pythagoras

 

Tilt measurements:

 

Tilt sensor:

 

Accuracy

 

(2 σ, standard deviation)

± 0.3°

- to laser beam

- to the housing

± 0.3°

Horizontal measurement

9

Indirect measurement

 

using tilt sensor (direct

9

horizontal distance)

 

Angle measurement using

9

tilt sensor(± 45°)

 

General:

 

EN

Distance measurements: Measuring accuracy* up to 10 m

(2 σ, standard deviation)

typically: ± 1/16 in* (± 1.0mm)

Laser class

II

Laser type

635 nm, < 1 mW

Ø laser point

6 / 30 / 60 mm

(at distances)

(10 / 50 / 100 m)

Autom. laser switch-off

after 3 min

Leica DISTO™ D330i 776751 en