![](/images/new-backgrounds/1283383/28338341x1.webp)
| Cause | Remedy |
252 | Temperature too | Cool down instrument |
| high |
|
253 | Temperature too | Warm up instrument |
| low |
|
255 | Receiver signal too | Use target plate |
| weak, measurement |
|
| time too long, |
|
| distance > 100 m |
|
256 | Received signal too | Target too reflective |
| strong | (use target plate) |
257Wrong measure- Darkentarget(measure
| ment, background | in different lighting |
| brightness too high | conditions) |
260 | Laser beam inter- | Repeat measurement |
| rupted |
|
|
|
|
Error | Cause | Remedy |
Error | Hardware error | Switch on/off the |
|
| device several times. If |
|
| the symbol still |
|
| appears, then your |
|
| instrument is defective. |
|
| Please call your dealer |
|
| for assistance. |
Technical data
Power Range | 0.05 m to 100 m | |
Technology™: | ||
Range (use target plate | 2 in. to 325 ft | |
from about 80m/260ft) |
| |
Smallest unit displayed | 0.1 mm/ 1/32nd | |
Distance measurement | 9 | |
Minimum/maximum |
| |
measurement, Continuous | 9 | |
measurement |
| |
Area/volume calculation of | 9 | |
room data | ||
| ||
Addition / subtraction | 9 | |
Indirect measurement | 9 | |
using Pythagoras | ||
| ||
Tilt measurements: |
| |
Tilt sensor: |
| |
Accuracy |
| |
(2 σ, standard deviation) | ± 0.3° | |
- to laser beam | ||
- to the housing | ± 0.3° | |
Horizontal measurement | 9 | |
Indirect measurement |
| |
using tilt sensor (direct | 9 | |
horizontal distance) |
| |
Angle measurement using | 9 | |
tilt sensor(± 45°) | ||
| ||
General: |
|
EN |
Distance measurements: Measuring accuracy* up to 10 m
(2 σ, standard deviation)
typically: ± 1/16 in* (± 1.0mm)
Laser class | II |
Laser type | 635 nm, < 1 mW |
Ø laser point | 6 / 30 / 60 mm |
(at distances) | (10 / 50 / 100 m) |
Autom. laser | after 3 min |
Leica DISTO™ D330i 776751 en