FLOOR PROTECTION

PLANNING YOUR INSTALLATION

FLOOR PROTECTION

This appliance requires non-combustible floor protec- tion for ember protection. If the floor protection is to be stone, tile, brick, etc., it must be mortared or grouted to form a continuous non-combustible surface. If a chim- ney connector extends horizontally over the floor, pro- tection must cover the floor under the connector and at least 2" (51 mm) to either side.

The floor protection must extend completely beneath the stove and to the front, sides, and rear as indicated:

USA REQUIREMENTS

16” (406 mm) min. to the front of the fuel door glass

8” (203 mm) min. beyond the sides of the fuel door opening

0” (0 mm) min. to the back of the stove body

CANADA REQUIREMENTS

18” (457 mm) min. to the front of the fuel door glass 8” (203 mm) min. beyond the sides of the stove body 8” (203 mm) min. to the back of the stove body

PAGE 5