INSTALLATION
FIREPLACE INSTALLATION
CHIMNEY
TERMINATION CAP
ENSURE CHIMNEY
IS SOUND
MASONRY FIREPLACE: USA APPROVED LINER – 6” DIA. FLEX OR
RIGID 24/26 MSG BLACK OR BLUED STEEL PIPE OR 2100°
HT LINER
CANADA APPROVED LINER –
S635 FLUE LINER
FACTORY BUILT (ZC)
FIREPLACE (USA ONLY) –
APPROVED LINER – 6” DI-
AMETER 2100° HT LINER
REMOVE FIRE-
PLACE DAMPER OR
SECURE OPEN
•USA only - All masonry fireplace installations re- quire a minimum positive flue connection using a
•Measure fireplace size to make certain the insert will fit before considering the installation.
MASONRY FIREPLACE REQUIREMENTS - This appli- ance may be installed in a masonry fireplace with an open- ing height of at least 21 inches (533 mm) using Masonry Fireplace Kit P/N 14M75. Installation into a masonry fire- place with an opening of 24” (610 mm) or higher does not require this header insulation kit. See page 26 for ordering information.
Masonry Fireplace Minimum Firebox Dimensions Minimum size required for fireplace firebox (recessed area into fireplace):
Height | 21” | (533 mm) |
Width at front of fireplace | 24 1/4” | (616 mm) |
Width at back of fireplace | 23 1/4” | (591 mm) |
Depth into fireplace | 15 3/4” | (400 mm) |
FACTORY BUILT FIREPLACE REQUIREMENTS – Note: In Canada, installation into a Factory Built Fireplace is not approved. When installing the 2800HT into a "high dome" or "low profile" type factory built fireplace (ZC), a ZC Fire- place kit is required (kit consists of components to insulate and allow for heat dissipation). See page 26 for ordering information.
Factory Fireplace Minimum Firebox Dimensions Minimum size required for fireplace firebox (recessed area into fireplace):
Min. unrestricted front opening: | 21” | (533 mm) |
Min. inside firebox height at flue opening: | 22” | (559 mm) |
Width at front of fireplace | 24 1/4” | (616 mm) |
Width at back of fireplace | 23 1/4” | (591 mm) |
Depth into fireplace | 15 3/4” | (400 mm) |
Side View of Typical
Do not face seal over
chimney cooling air system.
PAGE 8