15
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Planning Installation Safety and General
Operation
Maintenance
Troubleshooting
Parts / Accessories
OUTSIDE COMBUSTION AIR KIT INSTALLATIONFigure 16 - Outside Air Connection to Stove
Outside Air KitsOrder:
1 ea. P/N UZIAD Outside Air Coupler Kit (connects outside air ducting, UZI, to
stove)
AND
1 ea. P/N UZI Outside Air Ducting Kit (includes 4” insulated flex x 10’ long)
An outside air kit is required in Manufactured (mobile) Home installa-
tions. For residential installations, check with local authorities having
jurisdiction in your area, it may be mandatory.
Outside Air Kit Coupler
To install the outside air kit coupler onto the stove, line up the “V” notch
in the coupler with the “V” notch in the open on the bottom of the stove.
Push and twist so the rolled edge catches the bottom of the stove and
continue turning full 360° to lock the coupler in place.
Through the Wall Outside Air Kit Installation
(refer to Figures 15, 16 and 17)
The outside air assembly may be installed according to the following
requirements:
A) Duct length should be kept to a minimum.
B) The air intake register must not be installed more than ten (10) feet
(3050 mm) above the base of the stove.
C) The fresh air must come from outside the house. The air intake must
not draw air from the attic, from the basement or garage.
D) The air intake should be installed where it is not likely to be blocked by
snow or exposed to extreme wind and away from automobile exhaust
fumes, gas meters and other vents.
E) The duct and register may be installed above or below floor level.
- Make a 4-1/4” (110 mm) hole in the outside wall of the house at the
chosen location. From outside, place the outside air register in the
hole (open side down) and fasten the register to the wall, with screws
as shown (see Figure 17).
- Install the coupler onto the existing collar on stove (see Figure 15).
- Attach the duct to the coupler on stove (see Figure 16). Using the
aluminium tape provided, wrap the tape around the joint between the
flexible duct and the air inlet.
Figure 17 - Through the Wall, Outside Air Termination
Outside
Intake
OUTDOORS
INDOORS
Screw
Opening
Facing
Down
Wall
Aluminum Tape
Duct
Coupler (attached to
existing collar)
Duct
Manufactured Home Through the Floor Outside Air Kit Installa-
tion (refer to Figure 18)
Figure 18 - Manufactured Home Installation
Figure 15
Aluminum
Tape
Coupler (attached to
existing collar)
UZIAD Outside Air Coupler Duct
Aluminum
Tape
Installation