7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 4
Figure 3
Planning Installation Safety and General
Installation
Operation
Maintenance
Troubleshooting
Parts / Accessories
Footnotes:
1- These dimensions to the stove body are for reference
only. Actual distances should be measured from the
stove’s flue collar.
2- Minimum noncombustible hearth pad dimensions.
3- Clearances to connector pipe shall be measured from
the flue collar of the stove.
4- Not applicable to alcove installations.
INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 AND 4
Planning Installation
Stove
Stove
Stove
Alcove
Floor
Protection
Floor
Protection
Floor
Protection
Combustible Wall
Combustible Wall
Combustible
Wall
Alcove Depth
48" (1219mm) MAX.
E †
USA
E †
USA
K
K
J
D
C
B
AL
H
ITFF
GG
M
I
U
Corner Installation
Alcove or Parallel Installation
Alcove or Parallel Installation
Elbow
Elbow
Figure 2
Top View
Side View Top View
E
Canada
†
† See note 8
USA - inches (millimeters)
PIPE INSTALLATION A (3) B (1) C (3) D (1) E (8) F (1,4) G(3,4) H (2)
I
(6) J (2) K (7) L (5) M T (6) U
Single Wall Residential-Vertical Vent 16 12-3/8 22
12-1/2
8 5-11/16 16 38-5/8 51 33 16 0 90 58-7/8 N/A
(406) (314) (559) (318) (200) (145) (406) (981) (1295) (838) (406) (0) (2286) (1495) N/A
Single Wall Residential-With Elbow 19 15-3/8 23
13
-1/2 8 5-11/16 16 38-5/8 54 33 16 0 90 58-7/8 19
(483) (391) (584) (343) (200) (145) (406) (981) (1372) (838) (406) (0) (2286) (1495) N/A
Double Wall Residential or Mobile Home-Vertical Vent 10 6-3/8 20
10-1/2
8 4-11/16 15 38-5/8 45 33 16 0 90 57-1/2 N/A
(254) (162) (508) (267) (200) (119) (381) (981) (1143) (838) (406) (0) (2286) (1461) N/A
Double Wall Residential or Mobile Home-With Elbow 10 6-3/8 21
11-1/2
8 4-11/16 15 38-5/8 45 33 16 0 90 57-1/2 10
(254) (162) (533) (292) (200) (119) (381) (981) (1143) (838) (406) (0) (2286) (1461) N/A
Double Wall Alcove-Vertical Vent 13 9-3/8 22-1/2 13 8 N/A N/A 38-5/8 48 33 16 0 90 N/A N/A
(330) (238) (572) (330) (200) N/A N/A (981) (1219) (838) (406) (0) (2286) N/A N/A
CANADA - inches (millimeters)
PIPE INSTALLATION A (3) B (1) C (3) D (1) E (8) F (1,4) G(3,4) H (2) I (6) J (2) K (7) L (5) M T (6) U
Single Wall Residential-Vertical Vent 16 12-3/8 22
12-1/2
8 5-11/16 16 49 53 41-1/8 17-3/4 8 90 58-7/8 N/A
(406) (314) (559) (
318)
(200) (145) (406) (1235) (1346) (1045) (450) (200) (2286) (1495) N/A
Single Wall Residential-With Elbow 19 15-3/8 23
13-1/2
8 5-11/16 16 49 56 41-1/8 17-3/4 8 90 58-7/8 19
(483) (391) (584) (
343
) (200) (145) (406) (1235) (1422) (1045) (450) (200) (2286) (1495) (483)
Double Wall Residential or Mobile Home-Vertical Vent 10 6-5/16 20
10-1/2
8 4-11/16 15 47 47 41-1/8 17-3/4 8 90 57-1/2 N/A
(254) (160) (508) (
267
) (200) (119) (381) (1193) (1193) (1045) (450) (200) (2286) (1461) N/A
Double Wall Residential or Mobile Home-With Elbow 10 6-5/16 21
11-9/16
8 4-11/16 15 47 47 41-1/8 17-3/4 8 90 57-1/2 10
(254) (160) (533) (
293
) (200) (119) (381) (1193) (1193) (1045) (450) (200) (2286) (1461) (254)
Double Wall Alcove-Vertical Vent 13 9-3/8 22-1/2 13-1/16 8 N/A N/A 49 50 41-1/8 17-3/4 8 90 N/A N/A
(330) (238) (572) (331) (200) N/A N/A (1235) (1270) (1045) (450) (200) (2286) N/A N/A
5- In corner applications, when installed at minimum
back wall clearances, the required floor protection
is dimensioned off the back plane of the stove,
therefore the floor protection required off the
back corners (at a 45 degree angle) only needs to
extend to the wall. This situation will only occur in
CANADA installations.
6- Reference dimension only, to assist in planning the
installation.
7- Measured from front of floor protection to the front of
firebox.
8- USA=8” (200mm) from door opening, Canada=8”
(200mm) from sides and back of unit.