INSTALLATION
HORIZONTAL VENT TERMINATION REQUIREMENTS
The venting terminals should not be recessed into a wall or siding.
A = 2” Clearances above grade, veranda, porch, deck or
balcony.
B = 12” Clearance to window or door that may be opened.
C = 9” (USA) Clearance to permanently closed win- dow.12” (CAN)
D = 24” Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the
E = 12” Clearance to unventilated soffit. F = 9” Clearance to outside corner.
G = 6” Clearance to inside corner.
H = 3 ft. (USA) Not to be installed above a me- ter/regulator assembly within 3 feet (90 cm) hori- zontally from the
I = 3 ft. (USA) Clearance to service regulator vent out- let.
6 ft. (CAN)
J = 9” (USA) Clearance to
K = 3 ft. (USA) Clearance to a mechanical air supply inlet.
6 ft. (CAN)
L* = 7 ft. (USA)Clearance above paved
M**= 12” Clearance under veranda, porch, deck or bal- cony
*A vent shall not terminate directly above a
**Only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor.
•Note: Local Codes or Regulations may require differ- ent clearances.
PAGE 11