7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Mantel
Floor Protection
Combustible Wall
6”
(152mm)
9-1/2”
(241mm)
7-1/2”
(191mm)
10”
(254mm)
Max.
6”
(152mm)
23-3/8”
(594mm)
3”
(76mm)
1-1/2”
(38mm)
The  floor  protector  must  be  a  non-combustible  material  extending beneath the insert  from the surround  panels forward and  to the  front and sides as shown  in Figure 7.   Important, if anything  other than a masonry hearth is used in the installation you  must use the Heat Kit (Cat. No. 79024).Minimum Size Floor ProtectionOutline of Insert Base
Zero Clearance Kit and Heat Kit Installation    The Winslow™ PI40 insert has a Zero Clearance Kit (Cat. No. 79025) and a Heat Kit (Cat. No. 79024)  approved for new construction or  remodel installations. See Zero Clearance and Heat kit installation instructions at the back of this manual for requirements. Both kits have been tested and approved through OMNI Testing Laboratories Inc.6”
(152mm)
6”
(152mm) 3”
(76mm)
3”
(76mm)
6”
(152mm)
Insert Base
Firebox Front Edge
Floor Protection
31-3/4”
(807mm)
7-7/16”
(189mm)
19-1/4”
(489mm)
6-11/16”
(170mm)
6-11/16”
(170mm)
18-3/8”
(467mm)
Hearth Protection(shaded gray)Figure 6Figure 7Figure 8CLEARANCES TO COMBUSTIBLES