Note: Do not apply excessive pressure to any subsequent chimney sections following the stabilizer when installing. Ensure each subse- quent chimney section is securely attached by testing as noted in Step 4.

Step 6. Select the proper Security roof flash- ing based on pitch of roof. Use chart below for selection:

Roof Pitch

Model

 

 

Flat to 6/12

F8F6

 

 

6/12 to 12/12

F8F12

 

 

Next, slide roof flashing over extended chimney section that previously has been installed above

Step 8. Slide the FTF8 storm collar (ordered separately) over outer chimney, rest on flash- ing spacers and align with top surface of flash- ing. Insert tab in slot, pull tight and bend tab back over slot. Seal storm collar to outer chim- ney with roof caulking or mastic around entire circumference of pipe. Also add extra roof caulking to the tab/slot area to seal completely against water penetration (Figure 31 ). Check all joints very carefully to ensure no water intrusion can take place.

Locking Band

Waterproof

Step 10. Using a FTF8-CTD Round Termination:

1.Hold the FTF8-CTD over top of last chimney section (Figure 33 ).

2.Center inner slip section in inner flue pipe- slip down.

3.Center outer locking section over outer flue pipe. Push down until locking tabs are firmly engaged.

CTD Manual background

the roof opening in Step 4. FTF8 flashings require flashing spacers. Slide flashing all the way down until the flashing base rests flat on the roof (Figure 29 ). Again, check the vertical position of the chimney and the 2" minimum air space to combustibles.

Caulk

Termination

Figure 33

Chimney

10

FTF8 Chimney Manual background

Do Not Seal

Flashing Spacers Manual backgroundManual background

FTF8 Flashing Manual background

Figure 29

Note: Do not caulk or seal the ventilating open- ings.

Step 7. Secure flashing by nailing along the perimeter into roof using 8d nails or equivalent. If shingled roof, slide upper end and sides of roof flashing under shingles (trim if neces- sary), seal the top and both sides of the flashing to the roof with roof caulking. Cover nail heads with roof caulking (Figure 30 ).

Figure 30

Figure 31

Step 9. Security Chimneys locking bands, Model FLB, may be required if the chimney extends too high above the roof flashing. As a general rule, if the chimney extends more than 6' above the roof flashing, the use of locking bands is advisable to strengthen the chimney assembly. Align the locking band at the chim- ney joint. Locking bands wrap around pipe joints equally covering the joints of both pipe sections. Use the nut provided and TIGHTEN snugly. Do not overtighten as this might dam- age the chimney section (refer to Figure 31 ).

Note: If chimney extends more than 8' above roof surface, guy wires are also recommended. Use three (3) guy wires, attach to locking band assembly, extend and secure to roof in a trian- gular pattern (Figure 32 ). Guy wires are not supplied by the manufacturer.

Roof Ridge

120°

Figure 32

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

4.Pull up slightly on CTD to ensure locking joint has firmly engaged.

Using a FTF8-CTDT Chase Termination:

Refer to specific installation instructions in- cluded with the FTF8-CTDT chase termination for clearance and installation details.

Using a FTF8-CT1 Chase Termination:

Refer to specific installation instructions in- cluded with FTF8-CT1 chase terminations for clearance and installation details.

Using a FTF8-CT2 Chase Termination:

Refer to specific installation instructions in- cluded with FTF8-CT2 chase terminations for clearance and installation details.

Using a FTF8-CTT Chase Termination:

Refer to specific installation instructions in- cluded with FTF8-CTT chase terminations for clearance and installation details.

Using a FTF8-ATT Chase Termination:

Refer to specific installation instructions in- cluded with FTF8-ATT chase terminations for clearance and installation details.