![Parts Arrangement](/images/new-backgrounds/35478/354785x1.webp)
Parts Arrangement
PureAir® |
| Ignition Control |
|
Gas Valve | Board | Condenser | |
Air Purification System |
|
| |
|
| Coil | |
(Optional) |
|
| |
|
|
|
Evaporator
Coil
Control Box
Shipping & Packing List
1 − Assembled gas package unit
1 − Vent hood assembly with screen and screws
As soon as the unit is received, it should be inspected for possible damage during transit. If you find any damage, immediately contact the last carrier.
tested. The units require electric power, gas piping, condensate drain and duct connections at the point of installation. In addition, the heating vent hood must be installed before the unit is placed into operation
Safety Information
General
These installation instructions are intended as a general guide only, for use by an experienced, qualified contractor. The 15GCSX units are single−package air conditioners with two−stage gas heat designed for outdoor installation on a rooftop or a slab.
The unit must be sized based on heat loss and heat gain calculations made according to the methods of the Air Conditioning Contractors of America (ACCA).
The units are shipped assembled. All piping, refrigerant charge, and electrical wiring are factory−installed and
CAUTION
As with any mechanical equipment, personal injury can result from contact with sharp sheet metal edges. Be careful when you handle this equipment.
IMPORTANT
This unit is charged with HFC−410A refrigerant. Op- erating pressures for units charged with HFC−410A are higher than pressures in units charged with HCFC−22. All service equipment MUST be rated for use with HFC−410A refrigerant.