Lennox International Inc 51M32 Service Indicator, Thermostat RESET, Default Thermostat Settings

Models: 51M32

1 14
Download 14 pages 37.54 Kb
Page 5
Image 5
Service Indicator

Service Indicator

When abnormal equipment operation is detected, the SERVICE indicator will flash on the upper-right corner of the screen. This indicates that the equipment requires ser- vice from a qualified service technician. The SERVICE indi- cator is shown in figure 13.

Service Indicator Flashing

ROOM 73 SERVICE

FAN

AUTO

SYSTEM

HEAT

Figure 13

Thermostat RESET

Under some abnormal conditions, it may be desirable to at to its default condition. This can be

useful on rare occasions when the the thermostat is behav- ing abnormally (e.g. after an electrical storm or power out- age). The RESET button can be used to recover from this situation.

The RESET button is an unlabeled, recessed button lo- cated behind the door on the right−hand side of the thermo- stat, just below the SETTINGS button. The RESET button is visible in figure 3. Use a paper clip or small pencil to press the RESET button. After the RESET button is pressed, the thermostat settings will return to the defaults listed in the Default Settings section.

Default Thermostat Settings

Default thermostat settings are in table 1.

Table 1

Default Thermostat Settings

Mode

Heat

 

 

Setpoint

70°F (or 21°C)

 

 

Fan

Auto

 

 

Filter Reminder

OFF (reminder setting = 0)

 

 

Equipment Protection

reset back to zero

Timers

 

 

 

Technical Specifications

Thermostat Type

Electronic nonprogrammable thermostat for 1H/1C, gas or electric heat, non−heat pump, non−power robbing applica- tions.

Power Supply Range

18VAC − 30VAC (24VAC nominal), 60Hz

Temperature Display

Display Scale: Fahrenheit or Celsius user selectable (via DIP switches)

Display range: 35°F (2°C) to 99°F (37°C)

Display resolution: 1°F (1°C)

Display Accuracy: +/−1°F

Temperature Measurement Range

Measurement Scale: Fahrenheit

Measurement Range: 35°F to 99°F

Measurement Resolution: 0.5°F

Measurement Accuracy: +/−1°F

Field Offset: via DIP switches to +/−3°F

Sampling Method: temperature measurements sampled every 15 seconds. Displayed temperature is the average of the last four measurements.

Temperature Setpoint Range

Setting range: 50°F (10°C) to 90°F (32°C)

Setting resolution: 1°F (1°C)

Fan Control

AUTO or ON modes, gas or electric heat compatible via DIP switches (also see Thermostat Output section).

I/O Relays

All thermostat relays are latching type to minimize power consumption.

1.HEAT/COOL relay output

2.FAN relay output

3.SERVICE relay input

Equipment Protection Timers

Minimum Compressor OFF time: 5 minutes

Minimum Compressor ON time: 4 minutes

Minimum Furnace ON time: 3 minutes

Minimum furnace cycle time (elapsed time between any furnace activation and the next furnace activation): 6 min- utes.

Minimum elapsed time between any compressor activation and the next compressor activation: 6 minutes.

NOTE − All protection timers (except the compressor OFF timer) can be over−ridden if a heating or cooling demand is initiated or terminated using the UP, DOWN, HEAT, or COOL buttons.

Page 5

Page 5
Image 5
Lennox International Inc 51M32 Service Indicator, Thermostat RESET, Default Thermostat Settings, Technical Specifications