Humidification
BASIC & PRECISION
PRECISION, this adjustment controls the relative humidity (RH) be- tween 15 and 45%.
Scroll to HUMIDITY SETTINGS; press ENTER. Press the box below
HUMIDIFY.
HUMIDITY MODE
HUMIDIFY DEHUMIDIFY
Use up/down arrows to change the humidity setpoint (between 15 and 45%); press SAVE.
HUM SETPOINT |
|
DEFAULT (45%) | 4O% |
DEWPOINTif set up by the installer settings for DEWPOINT, this ad- justment (only when in heating mode) will change the humidification setpoint based on the outdoor temperature and a user−defined dew point adjustment setting. When humidifying, if condensation forms on the windows, the dewpoint should be adjusted in the range of −15 to −5%; if the home feels dry, set dewpoint upward in the range of +5 to +15%.
Scroll to HUMIDITY SETTINGS; press ENTER. Press the box below
HUMIDIFY.
HUMIDITY MODE
HUMIDIFY DEHUMIDIFY
Use up/down arrows to change the dewpoint (between +15 and −15%); press SAVE.
DEW POINT ADJ |
|
DEFAULT (O%) | −5% |
NOTE − Dewpoint adj available only when outdoor sensor is attached.
OFF
midify, this message appears when HUMIDITY SETTING is pressed:
HUMIDITY MODES OFF
If OFF is selected by the installer settings for HUMIDIFY but DE- HUMIDIFY is on, the dehumidification menu appears (this setpoint ad- just has NO effect on humidification):
DEHUM SETPOINT |
|
DEFAULT (5O%) | 45% |
506229−01 05/09 | Page 12 |