Setting Equipment

 

EL280DF UNIT

 

COOLING COIL

PROPERLY

PLENUM

SIZED FLOOR

 

OPENING

 

FIGURE 8

Return Air Opening −− Downflow Units

The following steps should be taken when installing ple- num:

1 − Bottom edge of plenum should be flanged with a hemmed edge (See figure 9).

PLENUM

SECURE FROM

 

OUTSIDE CABINET

Side View

 

 

HEMMED EDGE

SEALING STRIP (Field Provided)

CABINET SIDE PANEL

FIGURE 9 2 − Sealing strip should be used.

3 − In all cases, plenum should be secured to top flanges of furnace with sheet metal screws.

 

PLENUM

SECURE FROM IN-

Side View

SIDE CABINET

 

 

HEMMED EDGE

FIBERGLASS

 

SEALING STRIP

CABINET SIDE

 

(Field Provided)

PANEL

 

FIGURE 10

4 − In closet installations, it may be impossible to install sheet metal screws from the outside. In this case, make plenum with a removable front and install screws from the inside (See figure 10).

5 − Make certain that an adequate seal is made.

Setting Equipment

Manual backgroundWARNING

Do not install the furnace on its front, back or in the horizontal position. See figure 12. Do not connect the return air ducts to the back of the furnace. Doing so will adversely affect the operation of the safety con- trol devices, which could result in personal injury or death.

Install the EL280DF gas furnace as shipped in the down- flow position only. Do not install the furnace hori- zontally.

Select a location that allows for the required clearances that are listed on the unit nameplate. Also consider gas supply connections, electrical supply, vent connection, and installation and service clearances [24 inches (610

mm)at unit front]. The unit must be level.

NOTE − Units with 1/2 hp blower motors are equipped with three flexible legs and one rigid leg. See figure 11. The rigid leg is equipped with a shipping bolt and a flat white plastic washer (rather than the rubber mounting grommet used with a flexible mounting leg). The bolt and washer must be removed before the furnace is placed into opera- tion. After the bolt and washer have been removed, the rig- id leg will not touch the blower housing.

UNITS WITH 1/2 HP BLOWER MOTOR

RIGID LEG

remove shipping bolt and washer

FIGURE 11

Manual backgroundWARNING

The blower access panel must be securely in place when the blower and burners are operating. Gas fumes, which could contain carbon monoxide, can be drawn into living space resulting in personal inju- ry or death.

Page 9

Page 9
Image 9
Lennox International Inc EL280DF installation instructions Setting Equipment