Lennox International Inc G24M SERIES manual 2=CA#, Burner

Models: G24M SERIES

1 6
Download 6 pages 33.7 Kb
Page 5
Image 5
BURNER

UPFLOW FURNACE

BOTTOM RETURN AIR

FIGURE 4

UPFLOW FURNACE SIDE RETURN AIR

FIGURE 5

DOWNFLOW FURNACE

FILTERS IN PLENUM RACK

FIGURE 6

Blower

Check and clean blower wheel for any debris. Blower mo- tor is prelubricated for extended bearing life. No further lu- brication is needed.

2=CA#WARNING

Blower door must be securely in place when blower and burners are operating. Gas fumes, which could contain carbon monoxide, can be drawn into living space resulting in personal injury or death.

Burner Flame

The G24M burner flame is not adjustable; however, the flame should be inspected at the beginning of each heat- ing season and burners should be cleaned, if necessary. Burner flame should be blue when burning natural gas, blue/yellow when burning propane gas.

BURNER

BURNER FLAMEFLAME

FLAME APPEARS BLUE IF

BURNING NAT. GAS; BLUE/

YELLOW FOR PROPANE.HEAT

EXCHANGER

TUBE

VEST

PANEL

2=CA#

FIGURE 7

Page 5
Image 5
Lennox International Inc G24M SERIES manual 2=CA#, Burner