Blower
Check and clean blower wheel for any debris. Blower mo- tor is prelubricated for extended bearing life. No further lu- brication is needed.
WARNING
Blower door must be securely in place when blower and burners are operating. Gas fumes, which could contain carbon monoxide, can be drawn into living space resulting in personal injury or death.
Burner Flame
The G24M burner flame is not adjustable; however, the flame should be inspected at the beginning of each heat- ing season and burners should be cleaned, if necessary. Burner flame should be blue when burning natural gas, blue/yellow when burning propane gas.
BURNER | BURNER FLAMEFLAME |
FLAME APPEARS BLUE IF
BURNING NAT. GAS; BLUE/
YELLOW FOR PROPANE.HEAT
EXCHANGER
TUBE
VEST
PANEL