Filters

Placing Furnace Into Operation

G24M units are equipped with an electronic ignition system. Do not attempt to manually light burners on these furnaces. Each time the thermostat calls for heat, the burner will auto- matically light.

Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

THERMOSTATS

FIGURE 1

Gas Valve Operation

1 - STOP! Read the safety information at the beginning of this section.

2 - Set the thermostat to lowest setting. See figure 1. 3 - Turn off all electrical power to the unit.

4 - This furnace Is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

5 - Remove the access panel.

6 - White Rodgers 36E Gas Valve - Turn knob on gas valve

180Geither way to OFF. See figure 2.

Honeywell VR8205 Gas Valve - Turn knob on gas valve

clockwise2=CA" to OFF. Do not force. See figure 3.

7 - Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you do not smell gas go to next step.

HONEYWELL VR8205 SERIES GAS VALVE

ON

OFF

GAS VALVE SHOWN IN OFF POSITION

FIGURE 3

8 - White Rodgers 36E Gas Valve - Turn knob on gas valve 180Geither way to ON.

Honeywell VR8205 Gas Valve - Turn knob on gas

valve counterclockwiseUPFLOWDOWNFLOW to ON. Do not force. 9 - Replace the access panel.

10- Turn on all electrical power to unit.

11- Set the thermostat to desired setting.

NOTE-When unit is initially started, steps 1 through 11 may need to be repeated to purge air from gas line.

12- If the appliance will not operate, follow the instruc- tions “Turning Off Gas to Unit” and call your service technician or gas supplier.

Turning Off Gas to Unit

1 - Set the thermostat to the lowest setting.

2 - Turn off all electrical power to the unit if service is to be performed.

3 - Remove the access panel.

4 - Turn knob on White Rodgers gas valve 180Geither way to OFF; turn knob on Honeywell valve clockwiseManual background to OFF. Do not force.

5 - Replace the access panel.

Filters

WHITE RODGERS￿￿￿

36E SERIES GAS VALVE

2=CA"

GAS VALVE SHOWN IN OFF POSITION

FIGURE 2

G24M series units are equipped with external filters which should be inspected monthly and replaced when neces- sary to assure proper furnace operation. See table 1 for filter sizes. Replacement filters used with G24M-40/60/75 units must have a minimum velocity rating of 400 FPM. Replacement filters used with G24M-100/120/140 units require a minimum velocity rating of 625 FPM. Figures 4, 5 and 6 show possible filter locations.

TABLE 1

FILTER SIZE

MODEL NUMBER

UPFLOW

DOWNFLOW

 

 

 

 

1 FILTER

2 FILTERS

 

 

 

 

 

 

G24M-45/60/75

16 in. X 20 in. X 1 in.

16 in. X 20 in. X 1 in.

 

 

 

G24M-100/120/140

20 in. X 20 in. X 1 in.

16 in. X 20 in. X 1 in.

 

 

 