HONEYWELLVR8205SERIESGASVALVE |
ON |
WHITERODGEROFFS36EGASVALVE |
GASGASVVALVEALVESHWNSHOOWNININOFFOFFPOSIPOSITIONTION |
F IGUR E 3 |
7- Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instruc- tions. If you do not smell gas go to next step.
8- For Honeywell VR8205 gas valves, turn knob on gas
valve counterclockwise to ON. For White Rodgers 36E gas valves, move switch to ON. Do not force.
9- Replace unit access panel.
10- Turn on all electrical power to unit.
11- Set thermostat to desired setting.
12- If the appliance still will not operate, follow the instructions “To Turn Off Gas To Unit” and call your service technician or gas supplier.
To Turn Off Gas To Unit
1- Set thermostat to lowest setting.
2- Turn off all electrical power to unit if service is to be per- formed.
3- Remove unit access panel.
4- For Honeywell VR8205 gas valves, turn knob on gas
valve counterclockwise to OFF. For White Rodgers 36E gas valves, move switch to OFF. Do not force.
5- Replace unit access panel.
Filters
A filter must be in place anytime the unit is operating. The filter may be located in the unit or installed in a return air grille. Ask your dealer to show you the filter location. The filter should be inspected monthly and cleaned when nec- essary to assure proper furnace operation.
Filters CABINETused inside theBACKGHR26FILTERseriesCLIPunit are available from Lennox and must be ordered separately. These foam filters may be cleaned for reuse. If replacement is necessary, order Lennox part no. 31J81 for 14 X 25 inch filter for
F IGUR E 4
Cleaning Filter
1- Turn off electric power to furnace.
2- Remove blower access panel.
3- Remove filter by pressing side filter clips and pulling filter up and out.
4- Clean filter with cold water and a mild soap. Direct water through filter in the opposite direction of air flow. Remove all soap residue
5- Allow filter to dry then spray with filter handicoater
6- Replace filter in blower compartment under rear filter clip. Press on filter sides. Filter clips flex allowing filter to snap into place.
7- Replace blower access panel.
WARNING
Blower door must be securely in place when blower and burners are operating. Gas fumes, which could contain carbon monoxide, can be drawn into living space resulting in personal injury or death.
Seasonal Inspections
A qualified service technician should inspect the complete sys- tem each season (heating and cooling). The following mainte- nance procedures should be conducted by a qualified service technician. Do not attempt to service the unit in any way.
Page 4