Chapter 6. Installing hard disk drives and configuring RAID
This chapter contains information about installing hard disk drives and configuring
Redundant Array of Independent Disks (RAID) for this product.
Note: The information about configuring RAID in this chapter only applies for a
Windows environment. For information about configuring RAID in a Linux
environment, contact your Linux software provider.

Installing SATA or SAS hard disk drives and configuring RAID

This section contains information about the required number of SATAor SAS hard
disk drives for the supported level of RAID configuration.
Note: Your computer must have either all SATA hard disk drives or all SAS hard
disk drives installed. However, be sure that you do not install both the
SATAand SAS hard disk drives into the same computer.

Installing SATA or SAS hard disk drives

Your computer must have the minimum number of SATA or SAS hard disk drives
installed for the supported level of RAID below:
vRAID Level 0 – Striped disk array
Two hard disk drives minimum
Better performance without fault tolerance
vRAID Level 1 – Mirrored disk array
Two hard disk drives minimum
Improved read performance and 100% redundancy
vRAID Level 5 – Block-level striped disk array with distributed parity
Three hard disk drives minimum
Data striped at the byte level
Stripe error correction information
Better performance and fault tolerance
vRAID Level 10 – Combining features of RAID 0 and RAID 1
Four hard disk drives minimum
Very high reliability combined with high performance
Fault tolerance
To install a new SATA or SAS hard disk drive, refer to the installation procedure in
“Replacing a hard disk drive” in the ThinkStation Hardware Installation and
Replacement Guide.

Entering the Marvell BIOS Setup to configure SATA or SAS

RAID

This section describes how to enter the Marvell BIOS Setup to configure a SATAor
SAS RAID.
1. Turn on the computer after you have installed the required number of SATA or
SAS hard disk drives.
© Copyright Lenovo 2009 25