Lenovo 5214, 5354, 3425, 3980 manual Diagnostic error code FRU/Action

Models: 5354 3980 5214 3425

1 110
Download 110 pages 31.85 Kb
Page 64
Image 64

Diagnostic error code

 

FRU/Action

 

 

086-199-XXXMouse port interface test failed, cause

1. See “Undetermined problems” on page 64

unknown

2.

Flash the system and re-test. See “Updating

 

 

 

(flashing) BIOS from a disc” on page 99

 

3.

Replace component under function test

 

 

089-000-XXXMicroprocessor test passed

No action

 

 

089-XXX-XXXMicroprocessor failure

1. Microprocessor(s)

 

2.

System board

 

 

089-195-XXXMicroprocessor test aborted by user

Information only Re-start the test, if necessary

 

 

 

089-196-XXXMicroprocessor test halt, error threshold

1.

Press F3 to review the log file

exceeded

2.

Re-start the test to reset the log file

 

 

 

089-197-XXXMicroprocessor test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using the

 

 

Setup Utility” on page 41

 

2.

Re-run test

 

3.

Replace the component that is called out in warning

 

 

statement

 

4.

Replace the component under test

 

 

089-198-XXXMicroprocessor test aborted

1. Flash the system. See “Updating (flashing) BIOS

 

 

from a disc” on page 99

 

2.

Go to “Undetermined problems” on page 64

 

 

089-199-XXXMicroprocessor test failed, cause unknown

1. See “Undetermined problems” on page 64

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) BIOS from a disc” on page 99

 

3.

Replace component under function test

 

 

170-000-XXXVoltage sensor(s) test passed

No action

 

 

170-0XX-XXXVoltage sensor(s) failure

1. Flash system

 

2.

System board

 

 

170-195-XXXVoltage sensor(s) test aborted by user

Information onlyRe-start the test, if necessary

 

 

 

170-196-XXXVoltage sensor(s) test halt, error threshold

1.

Press F3 to review the log file

exceeded

2.

Re-start the test to reset the log file

 

 

 

170-197-XXXVoltage sensor(s) test warning

1. Make sure the component that is called out is

 

 

connected and/or enabled. See Chapter 6 “Using the

 

 

Setup Utility” on page 41

 

2.

Re-run test

 

3.

Replace the component that is called out in warning

 

 

statement

 

4.

Replace the component under test

 

 

170-198-XXXVoltage sensor(s) test aborted

1. If a component is called out, make sure it is

 

 

connected and/or enabled. See Chapter 6 “Using the

 

 

Setup Utility” on page 41

 

2.

Flash the system and re-test. See “Updating

 

 

(flashing) BIOS from a disc” on page 99

 

3.

Go to “Undetermined problems” on page 64

 

 

 

58Hardware Maintenance Manual

Page 64
Image 64
Lenovo 5214, 5354, 3425, 3980 manual Diagnostic error code FRU/Action