6(-)

5

4

1(+)2(+)

3

7(-)

Terminal Voltage (V dc)
1 + 0 to + 12.6
7 Ground (−)
3. If the voltage is less than +11.0 V dc, the battery pack has been discharged.

Note: Recharging will take at least 3 hours, even if the indicator does not turn

on.
If the voltage is still less than +11.0 V dc after recharging, replace the battery.
4. If the voltage is more than +11.0 V dc, measure the resistance between battery
terminals 4 and 7. The resistance must be 4 to 30 K .
If the resistance is not correct, replace the battery pack. If the resistance is

correct, replace the system board.

Checkout guide
28 MT 0689, 0690, 0768