52 Service Manual
4039-1XX
Adjustments
Envelope Restraint Spring On The Envelope+ Feeder
1. Loosen the mounting screw [A].
2. Position the spring [B] so it clears the separator roller by
1.9 ±0.2 mm (0.075 ±0.008 in.).
3. Tighten the mounting screw.
Paper Restraint Spring On The 100-sheet
Auxiliary Feeder
1. Loosen the mounting screw [A].
2. Position the spring [B] so it clears the separator roller by
1.9 ± 0.2 mm (0.040 ±0.008 in.).
3. Tighten the mounting screw.